Snap Action Rotary Bridging Tap Changer (41C)

Used for switching the tap positions on HV windings to adjust the voltage for Small Power transformers.

  • 110, 150, 200, 250kV BIL, up to 350 kV BIL
  • Five (5) or Seven (7) position
  • 200, 400, 600, 700, 800 and 1000 AMPs.
  • With standard or Flexible Universal joint
  • With T handle and index plate
  • Bolt threaded studs

Snap Action Rotary Bridging Tap Changer (44B)

Used as the tap changer to adjust voltage of distribution transformers.

  • 450 kV BIL, 550 kV BIL, up to 750 kV BIL
  • Five (5) or Seven (7) position
  • 200, 400 or 600 AMPs.
  • With standard or Flexible Universal joint
  • With T handle and index plate
  • Crimped studs

Half Moon Bridging Tap Changer (40B)

Used for switching the tap positions on windings to adjust the voltage for Large Distribution Transformers.

  • 110kV BIL, 150kV BIL, 200 kV BIL & 250 kV BIL,
  • Five (5) position
  • 200, 400, 600, 700, 800 AMPs.
  • With standard or Flexible Universal joint
  • With T handle and index plate
  • Bolt threaded studs

Linear Type Series Parallel (22L)

Used in Small and Medium Power Transformers for connecting portion of windings (usually HV Windings ) in series or parallel connection to change transformer ratio.

  • 95kV BIL, 125, kV BIL, and 200 kV BIL up to 250 kV BIL
  • Two (2) position (series/parallel)
  • One (1) to Three (3) columns phases

Linear Type Bridging Style Tap Changer (45L)

Used for switching the tap positions on windings to adjust the voltage for Large Distribution & Small Power Transformers.

  • From 110, up to 350 kV BIL
  • Five (5) or Seven (7) position
  • 200, 400, or 600 AMPs.
  • With Geneva mechanism.

Linear Type Bridging Style Tap Changer (46L)

Used for switching the tap positions on windings to adjust the voltage for Large Distribution & Small Power Transformers.

  • 30 – 200 kV BIL
  • 500 to 2000 manually operated or
  • up to 6000 motor operated
  • 2 to 13 positions

Series Parallel (22B)

Used in Small and Medium Power Transformers for connecting windings (usually HV) in series or parallel connection to change transformer ratio.

  • 125, kV BIL, and 150 kV BIL up to 200 kV BIL
  • 500 AMPs
  • Two (2) position (series/parallel)
  • One (1) to Three (3) phases

Delta Wye (26B)

Used in Small and Medium Power Transformers for connecting windings in Delta or WYE connection to change transformer ratio.

  • 125, kV BIL, and 150 kV BIL
  • 500 Amps to 2000 Amps
  • Two (2) position
  • 36 deg. or 72 deg. rotation T- handle with pad lock or pull to turn.

Dual Voltage (24B)

 

  • 150 kV BIL or 200 kV BIL
  • 500 Amp to 850 Amps , (per deck)
  • Two (2) position Three (3) phase (3, 6 or 9 decks)
  • Side wall mount with right angle gearbox.
  • With Universal Joint, Gear Box
  • 36 or 72 degree rotation

Grounding Network Switches

Used on network transformers for disconnecting the primary feeder from the transformer and connecting incoming feeder to the ground.

  • 95kV BIL, 125, kV BIL, and 200 kV BIL
  • Two (2) position (open/ground) or Three (3) position (open/closed/ground)
  • Side wall mount, with welded or bolted front plate.
  • Single or Double solenoids.
  • Magnetic break assembly on closed contact,
  • Phase sequence grounding.

Bladed – Bridging & Common Center (43B)

  • 30 – 200 kV BIL
  • 500 to 2000 manually operated or
  • up to 6000 motor operated
  • 2 to 13 positions

Bridging Ring Style Tap Changer (42B)

Used as the tap changer to adjust voltage of distribution transformers.

  • 125 and 200AMP,
  • Wall mount and right angle drive,
  • three(3) and five (5) position
  • One(1) two (2), three (3) and six (6) decks
  • 15kV / 110 kV BIL or 46 kV / 250 kV BIL

Motor operated Oil switches (34B series)

Common Center or Bridging style, used for switching position in Testing equipment, distribution, air-core reactor- wind turbine etc

  • 200 to 6500 AMP,
  • 600 volts to 46kV
  • Up to 8 position.